You Are Here : Home >> News >> Product News >> New product fat girl ps20 series spectrocolorimeter

New fat girl ps20 series spectrocolorimeter

Hits:         Date:2022-10-13
New produce fat girl PS20 series spectroclorimeter adopt CMOS dual beam splitting sensor, d/8 optical structurer and SCI/SCE mode, which is more precise than colorimeter. Some models will include UV light source, and some models have many apertures. Their big differences are accuracy and stable.

New product fat girl ps20 series spectrocolorimeter

New product fat girl ps20 series spectrocolorimeter

New produce fat girl PS20 series spectroclorimeter adopt CMOS dual beam splitting sensor, d/8 optical structurer and SCI/SCE mode, which is more precise than colorimeter. Some models will include UV light source, and some models have many apertures. Their big differences are accuracy and stable. 

Here is the specifcation for them and their differneces are very clearly in the table. 

Model PS2010 PS2020 spectrocolorimeter PS2030 PS2040 spectrocolorimeter PS2050 PS2060 spectrocolorimeter PS2070 PS2080 spectrocolorimeter
Optical Geometry D/8(diffused illumination, 8-degree viewing angle), SCI/SCE (specular component included/specular component excluded) Mode, Comply toCIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7
Characteristic Adopt CMOS dual beam splitting sensor;Used for color difference quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries. Adopt CMOS dual beam splitting sensor;Used for color difference quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries, also for fluorescence sample measurement.
Light Source Combined full spectrum LED light source Combined full spectrum LED light source, UV light source
Integrating Sphere Size Φ40mm
Sensor CMOS dual beam splitting sensor
Wavelength Range 400-700nm
Measuring Aperture PS2010 Single aperture:Φ8mm flat PS2030 Two Apertures:MAV:Φ8mm/Φ10mm PS2050 Two Apertures:MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm PS2070 Four Apertures:MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm
PS2020 Single aperture:Φ4mm flat PS2040 Two Apertures:SAV:Φ4mm/Φ5mm  PS2060 Three Apertures:MAV:Φ8mm;SAV:Φ4mm;LAV:1x3mm PS2080 Six Apertures:MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm;LAV:1x3mm
Specular Component SCI/SCE
Color Space CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99
Color Difference Formula ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter)
Other Colorimetric Index Spectral reflectance, WI(ASTM E313,CIE/ISO,AATCC,Hunter), YI(ASTM D1925,ASTM 313),Metamerism Index Mt,Staining Fastness, Color Fastness,Color Strength, Opacity,555 tone classification, Munsell(C/2)(Mobile APP implementation)
Observer Angle 2°/10°
Illuminant D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30),U35,NBF,ID50,ID65
Display Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Simulation, Color Offset
Measuring Time About 1s
Repeatability Chromaticity value: MAV/SCI, within ΔE*ab 0.04 (After preheating and correction, the average value of the whiteboard was measured for 30 times at an interval of 5s);Spectral reflectance: MAV/SCI, Standard deviation within 0.1% (400 nm to 700 nm: within 0.2%) Chromaticity value: MAV/SCI, within ΔE*ab 0.035 (After preheating and correction, the average value of the whiteboard was measured for 30 times at an interval of 5s);Spectral reflectance: MAV/SCI, Standard deviation within 0.1% (400 nm to 700 nm: within 0.2%) Chromaticity value: MAV/SCI, within ΔE*ab 0.03 (After preheating and correction, the average value of the whiteboard was measured for 30 times at an interval of 5s);Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%) Chromaticity value: MAV/SCI, within ΔE*ab 0.02 (After preheating and correction, the average value of the whiteboard was measured for 30 times at an interval of 5s);Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%)
Inter-instrument Error MAV/SCI, Within ΔE*ab 0.4
(Average for 12 BCRA Series II color tiles)
MAV/SCI, Within ΔE*ab 0.35
(Average for 12 BCRA Series II color tiles)
MAV/SCI, Within ΔE*ab 0.3
(Average for 12 BCRA Series II color tiles)
MAV/SCI, Within ΔE*ab 0.2
(Average for 12 BCRA Series II color tiles)
Displayed Accuracy 0.01
Measured Reflectance Range 0-200%
Reflectance Resolution 0.01%
Measurement Mode Single Measurement, Average Measurement(2-99times)
Locating Method Stabilizer position Stabilizer position+camera locating
White Calibration mode Contact type automatic calibration Non-contact automatic calibration
Dimension 94X68X188mm
Weight About 270g
Battery Lithium battery,3.7V,5000mAh,8000 cycles in 8 hours
Illuminant Life Span More than 1.2 million measurements over 10 years
Screen 2.8 inch TFT true color, Capacitive Touch Screen
Interface USB USB,Bluetooth®5.0
Data Storage Standard 500 Pcs, Sample 5000 Pcs(One data is able to include SCI/SCE);PC mass storage Standard 500 Pcs, Sample 10000 Pcs(One data is able to include SCI/SCE);PC mass storage
Software support Windows Andriod,IOS,Windows,Wechat small program, Hongmeng
Language Simplified Chinese, English, Traditional Chinese
Operating Environment 0~40℃, 0~85%RH (no condensing),Altitude < 2000m
Storage Environment  -20~50℃, 0~85%RH (no condensing)
Standard Accessory Power Adapter, USB Cable, User Guide, SQCX PC Software(Download from office website), White and Black Calibration Cavity, Protective Cover, Wrist strap, Aperture
Optional Accessory USB Micro Printer, Powder Test Box
Notes Technical parameters are only for reference, subject to the actual sale of the product
6-8/F,Building B33,Low-Carbon Headquarters Park,400 Xincheng Avenue,Zengcheng District,Guangzhou,P.R.China.